Abstract Background Increasing evidence has been presented which suggests that left ventricular (LV) diastolic dysfunction may play an important role in the development of atrial fibrillation (AF). However, the potential for LV diastolic dysfunction to serve as a predictor of AF recurrence after radiofrequency catheter ablation remains unresolved. Methods Dual Doppler and M-PW mode echocardiography were performed in 67 patients with AF before ablation and 47 patients with sinus rhythm. The parameters measured within identical cardiac cycles included, the time interval between the onset of early transmitral flow peak velocity (E) and that of early diastolic mitral annular velocity (e’) (TE-e’), the ratio of E to color M-mode Doppler flow propagation velocity (Vp)(E/Vp), the Tei index, the ratio of E and mitral annular septal (S) peak velocity in early diastolic E/e’(S) and the ratio of E and mitral annular lateral (L) peak velocity E/e’(L). A follow-up examination was performed 1 year after ablation and patients were divided into two groups based on the presence or absence of AF recurrence. Risk estimations for AF recurrence were performed using univariate and multivariate logistic regression. Results TE-e’, E/Vp, the Tei index, E/e’(S) and E/e’(L) were all increased in AF patients as compared with the control group (p