Background: The non–ST-segment–elevation myocardial infarction (NSTEMI) guidelines of the European Society of Cardiology (ESC) recommend a 3h cardiac troponin determination in patients triaged to the observe-zone of the ESC 0/1h-algorithm; however, no specific cutoff for further triage is endorsed. Recently, a specific cutoff for 0/3h high-sensitivity cardiac troponin T (hs-cTnT) change (7 ng/L) was proposed, warranting external validation. Methods: Patients presenting with acute chest discomfort to the emergency department were prospectively enrolled into an international multicenter diagnostic study. Final diagnoses were centrally adjudicated by 2 independent cardiologists applying the fourth universal definition of myocardial infarction, on the basis of complete cardiac workup, cardiac imaging, and serial hs-cTnT. Hs-cTnT concentrations were measured at presentation, after 1 hour, and after 3 hours. The objective was to externally validate the proposed cutoff, and if necessary, derive and internally as well as externally validate novel 0/3h-criteria for the observe-zone of the ESC 0/1h-hs-cTnT-algorithm in an independent multicenter cohort. Results: Among 2076 eligible patients, application of the ESC 0/1h-hs-cTnT-algorithm triaged 1512 patients (72.8%) to either rule out or rule in NSTEMI, leaving 564 patients (27.2%) in the observe-zone (adjudicated NSTEMI prevalence, 120/564 patients, 21.3%). The suggested 0/3h-hs-cTnT-change of Conclusions: A combination of a 3h-hs-cTnT concentration ( Registration: URL: https://clinicaltrials.gov ; Unique identifier: NCT00470587.