In this paper, the authors propose a new strategy for the command of the three-phase voltage inverter's switches. After a recall of the principle on which the Delta-Sigma modulation single-phase converter works, they emphasize the avantages it provides and they show how this strategy can be extended to the three-phase voltage inverter by a vectorial approach. Compared to usual modulations and space vector modulation techniques that are now frequently to be found, for identical average switching frequency, this process improves the quality of the output voltages applied to the load. The numerical simulation results are presented. Dans cet article, les auteurs proposent une nouvelle strat?gie de commande des interrupteurs d'un onduleur de tension triphas?. Apr?s avoir rappel? le principe de la modulation Delta Sigma utilis?e pour les convertisseurs monophas?s, et soulign? les avantages qu'elle apporte, ils montrent comment cette strat?gie peut ?tre ?tendue au cas de l'onduleur de tension triphas? par une approche vectorielle. Par rapport aux modulations classiques et aux techniques de ?Modulation du Vecteur d'Espace", que l'on rencontre aujourd'hui fr?quemment et pour une fr?quence moyenne de commutation identique, ce proc?d? am?liore la ?qualit?" des tensions de sortie appliqu?es ? la charge. Les r?sultats de la simulation num?rique sont pr?sent?s.