245 00 a3상 전압형 PWM 컨버터의 정현추종 전원전류제어 /d許泰遠
260 a부산 :b동아대학교,c1999
300 aiii,34장. :b삽도 ;c26cm
502 a학위논문(석사)b동아대학교 대학원 :c전기공학과,d1999
520 b영문초록 : This paper presents the sinusoidal tracking current control system in order to eliminate the steady state control error and to improve the transient characteristics for three-phase voltage source PWM converter. A general mathematical model with switching functions of the PWM converter that is represented as differential equations is established. The proposed sinusoidal tracking current control system that does not require coordinate transformations is described. It is proved that the steady state deviation reduces to zero from a transfer function of source current control system. The sinusoidal tracking control model is realized by differential equations for the LC equivalent circuit. From simulations and experimental work, it is verified that the control system can eliminate the steady state error of source current and also improve the transient state characteristic.
520 b한글초록 : 전력용 스위칭 소자의 고속·대용량화가 가능해짐에 따라서 전력전자 분야의 발전이 가속화되고 있다. 그러나 변환기의 전원측에서 발생하는 고조파나 무효전력이 문제시되고 있으며, 선진국에서는 가전·범용품을 대상으로 고조파발생 기준을 정하여 규제하고 있다. 따라서, 전원측의 고조파를 제거할 수 있고, 모터 구동 시스템에서 제동시 전원측으로의 전력회생이 가능한 전압형 PWM 컨버터에 대한 관심이 증대되고 있으며, 여러 제어기법들이 적용되고 있다. 본 논문에서는 전압형 PWM 컨버터의 스위칭 패턴에 따른 전원전류 파형을 MODE 별로 분석하고, 스위칭 함수를 이용한 수학적 모델을 제시한다. 전원전류 제어기로서 정현추종 제어기를 제안하며, 좌표변환을 필요로 하지 않는 간단한 알고리즘으로 제어계를 구성한다. 제안하는 정현추종 제어기는 LC 등가회로로부터 구현되며, 전원전류 제어계의 전달함수를 통하여 전원전류가 지령치에 완벽하게 추종됨을 확인하고 시뮬레이션을 행한다. 또한, IGBT(Insulated Gate Bipolar Transistor)를 스위칭 소자로 사용한 3상 전압형 컨버터를 구성하고, 정현추종 제어기를 적용한 실험으로부터 본 논문에서 제안하는 방식의 타당성을 확인하고자 한다.
653 aLC 등가회로
856 adonga.dcollection.netuhttp://donga.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000002141667
950 0 a비매품b\3000c(추정가)
3상 전압형 PWM 컨버터의 정현추종 전원전류제어
종류
학위논문 동서
서명
3상 전압형 PWM 컨버터의 정현추종 전원전류제어
저자명
발행사항
부산 : 동아대학교 1999
형태사항
iii,34장 : 삽도 ; 26cm
학위논문주기
학위논문(석사) 동아대학교 대학원 : 전기공학과, 1999
주기사항
영문초록 : This paper presents the sinusoidal tracking current control system in order to eliminate the steady state control error and to improve the transient characteristics for three-phase voltage source PWM converter. A general mathematical model with switching functions of the PWM converter that is represented as differential equations is established. The proposed sinusoidal tracking current control system that does not require coordinate transformations is described. It is proved that the steady state deviation reduces to zero from a transfer function of source current control system. The sinusoidal tracking control model is realized by differential equations for the LC equivalent circuit. From simulations and experimental work, it is verified that the control system can eliminate the steady state error of source current and also improve the transient state characteristic. / 한글초록 : 전력용 스위칭 소자의 고속·대용량화가 가능해짐에 따라서 전력전자 분야의 발전이 가속화되고 있다. 그러나 변환기의 전원측에서 발생하는 고조파나 무효전력이 문제시되고 있으며, 선진국에서는 가전·범용품을 대상으로 고조파발생 기준을 정하여 규제하고 있다. 따라서, 전원측의 고조파를 제거할 수 있고, 모터 구동 시스템에서 제동시 전원측으로의 전력회생이 가능한 전압형 PWM 컨버터에 대한 관심이 증대되고 있으며, 여러 제어기법들이 적용되고 있다. 본 논문에서는 전압형 PWM 컨버터의 스위칭 패턴에 따른 전원전류 파형을 MODE 별로 분석하고, 스위칭 함수를 이용한 수학적 모델을 제시한다. 전원전류 제어기로서 정현추종 제어기를 제안하며, 좌표변환을 필요로 하지 않는 간단한 알고리즘으로 제어계를 구성한다. 제안하는 정현추종 제어기는 LC 등가회로로부터 구현되며, 전원전류 제어계의 전달함수를 통하여 전원전류가 지령치에 완벽하게 추종됨을 확인하고 시뮬레이션을 행한다. 또한, IGBT(Insulated Gate Bipolar Transistor)를 스위칭 소자로 사용한 3상 전압형 컨버터를 구성하고, 정현추종 제어기를 적용한 실험으로부터 본 논문에서 제안하는 방식의 타당성을 확인하고자 한다.
관련 URL

소장정보

청구기호 : 564.8 허883삼
도서예약
서가부재도서 신고
보존서고신청
캠퍼스대출
우선정리신청
검색지인쇄
등록번호 청구기호 별치기호 소장위치 대출상태 반납예정일 서비스
등록번호
E0581981
청구기호
564.8 허883삼 =2
별치기호
D
소장위치
부민학위논문실
대출상태
대출불가 (소장처별 대출 불가)
반납예정일
서비스
등록번호
E0598249
청구기호
564.8 허883삼
별치기호
D
소장위치
부민학위논문실
대출상태
대출불가 (소장처별 대출 불가)
반납예정일
서비스

책소개

전체 메뉴 보기