In this paper, to check robust stability for higher order interval systems a step-by-step procedure is presented using simple conditions, on the basis of Routh criterion. In this, it is pointed out that there is no need to apply Routh criterion to all the four Kharitonov’s polynomials in some class of control system problems, and hence reduces the computational cost. Numerical examples illustrate the procedure.