In this study, to develop warm, humidity-sensitive IoT cooling and heating chairs, efficiency was confirmed through flow analysis and performance test of the amount of mass flow by changing the structure of the airway of the seat plate, which is the seat of the chair. The performance test to verify the efficiency of course is the flow analysis according to the structural change and the ventilation volume in the seat sponge of the chair are measured and their results are compared and analyzed. Though the design was based on the best physical condition of the seated person in the first design, it can not expected the results of air velocity and mass flow due to the angular structure of the airway due to the physical conditions of the seated person. And the increase in average mass flow was insufficient in the secondary design of the U-shaped circular structure considering the physical conditions of the seated person first. So there was a limit to actually applying it to the manufacture of air-conditioning chairs. It was confirmed that the cooling and heating effect was the greatest to reduce the occurrence of mass flow loss and secure the maximum air velocity and volume in the third design of a simple structure to minimize airflow loss.
본 연구에서는 온, 습도 감응형 IoT 냉, 난방 의자를 개발하기 위하여 의자의 좌면인 좌판의 통기로에 대한 구조 변경을 통하여 송풍량을 유동 해석과 성능 시험을 통하여 효율성을 확인하였다. 효율성을 확인하기 위한 성능 시험은 구조 변경에 따른 유동해석과 의자 좌면 스펀지에서의 송풍 풍량을 측정하여 각각의 결과를 비교 분석하였다. 1차 설계시 착좌자의 신체적 조건을 최상으로 고려하여 설계를 하였지만 오히려 착좌자의 신체적 조건으로 인한 통기로의 각형 구조로 인하여 풍속과 풍량이 기대에 못미치는 결과를 얻었고, U자형 원형 구조의 2차 설계는 착좌자의 신체적 조건을 우선 고려하다 보니 평균 풍속과 풍량의 증가가 미비하여 실제로 냉난방 의자의 제작에 적용하기에는 한계가 있었다. 풍량 손실을 최소화하기 위한 단순 구조의 3차 설계에서는 풍량 손실의 발생을 억제하여 풍속과 풍량을 최대한 확보할 수 있어서 냉난방 효과가 제일 큰 것으로 확인되었다.