A new test method for electrical conductivity of aviation fuel
- Resource Type
- Conference
- Authors
- Zheng, Lianying; He, Chaolai
- Source
- 2008 Conference on Precision Electromagnetic Measurements Digest Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on. :576-577 Jun, 2008
- Subject
- Fields, Waves and Electromagnetics
Testing
Fuels
Electrodes
Capacitance
Conductivity measurement
Coaxial components
Dielectric constant
Electrostatic measurements
Dielectric measurements
Petroleum
- Language
- ISSN
- 0589-1485
2160-0171
A new coaxial cylindrical cell with guard electrodes has constructed and a unique approach to determine the cell constant by means of capacitance of the cell in air has been presented. The new cell is very stable in both construction and performance. With this technique, an uncertainty of 0.1% in measuring conductivity of aviation fuel and other liquids can be achieved.