Abstract Background To observe the occurrence of related complications after self-expandable metallic (SEM) airway stents implantation with different diameters at different time points, and to provide theoretical basis for the optimal chioce of existing airway stents in clinical practice. Methods Healthy New Zealand white rabbits were used to establish benign tracheal stenosis models after chest CT examination. Forty-fivemodel rabbits with more than 50% of airway stenosis were divided into two groups. Small-diameter SEM stents (The ratio of stent diameter to airway diameter is nearly 1.0) were implanted in Group A in 21 rabbits, and large-diameter tracheal stents (The ratio of stent diameter to airway diameter is more than 1.2) were implanted in Group B in 24 rabbits. Stent-related complications were observed after stent implantation in 2nd,4th,8th, and 12th week by bronchoscopygross anatomy, pathological and the expressions of IL-1RA, IL-8 and MMP9 in involved tracheal. Results The incidence rate of tracheomalacia of stent was significantly higher in group B (24/24 100%) than that in group A (1 /21,4.8%) (P