Abstract Background Pressure pain thresholds (PPTs) are commonly assessed to quantify mechanical sensitivity in various conditions, including migraine. Digital and analogue algometers are used, but the concurrent validity between these algometers is unknown. Therefore, we assessed the concurrent validity between a digital and analogue algometer to determine PPTs in healthy participants and people with migraine. Methods Twenty-six healthy participants and twenty-nine people with migraine participated in the study. PPTs were measured interictally and bilaterally at the cephalic region (temporal muscle, C1 paraspinal muscles, and trapezius muscle) and extra-cephalic region (extensor carpi radialis muscle and tibialis anterior muscle). PPTs were first determined with a digital algometer, followed by an analogue algometer. Intraclass correlation coefficients (ICC3.1) and limits of agreement were calculated to quantify concurrent validity. Results The concurrent validity between algometers in both groups was moderate to excellent (ICC3.1 ranged from 0.82 to 0.99, with 95%CI: 0.65 to 0.99). Although PPTs measured with the analogue algometer were higher at most locations in both groups (p