BACKGROUND AND AIM: A recently carried out randomized controlled trial showed the benefit of a novel 20-G fine-needle biopsy (FNB) over a 25-G fine-needle aspiration (FNA) needle. The current study evaluated the reproducibility of these findings among expert academic and non-academic pathologists. METHODS: This study was a side-study of the ASPRO (ASpiration versus PROcore) study. Five centers retrieved 74 (59%) consecutive FNB and 51 (41%) FNA samples from the ASPRO study according to randomization; 64 (51%) pancreatic and 61 (49%) lymph node specimens. Samples were re-reviewed by five expert academic and five non-academic pathologists and rated in terms of sample quality and diagnosis. Ratings were compared between needles, expert academic and non-academic pathologists, target lesions, and cytology versus histological specimens. RESULTS: Besides a higher diagnostic accuracy, FNB also provided for a better agreement on diagnosing malignancy (ĸ = 0.59 vs ĸ = 0.76, P