International audience; Objective: Two tools are currently available in the literature to evaluate the usability of medication alert systems, the instrument for evaluating human factors principles in medication-related decision support alerts (I-MeDeSA) and the tool for evaluating medication alerting systems (TEMAS). This study aimed to compare their convergent validity, perceived usability, usefulness, strengths, and weaknesses, as well as users' preferences.Method: To evaluate convergent validity, two experts mapped TEMAS' items against I-MeDeSA's items with respect to the usability dimensions they target. To assess perceived usability, usefulness, strengths, and weaknesses of both tools, staff with expertise in their medication alerting system were asked to use French versions of the TEMAS and I-MeDeSA. After the use of each tool, participants were asked to complete the System Usability Scale (SUS) and answer questions about the understandability and usefulness of each tool. Finally, participants were asked to name their preferred tool. Numeric scores were statistically compared. Free-text responses were analyzed using an inductive approach.Results: Forty-five participants from 10 hospitals took part in the study. In terms of convergent validity, I-MeDeSA focuses more on the usability of the graphical user interface while TEMAS considers a wider range of usability principles. Both tools have a fair level of perceived usability (I-MeDeSA' SUS score = 61.85 and TEMAS' SUS score = 62.87), but results highlight that revisions are necessary to both tools to improve their usability. Participants found TEMAS more useful than I-MeDeSA (t = -3.63, p =.005) and had a clear preference for TEMAS to identify problems in formative evaluation (39 of 45; 0.867, p