Deep levels in Se- and Pb-doped bulk TlBr detectors were characterized with photo-induced conductivity transient spectroscopy (PICTS) and cathodoluminescence (CL). Se-doped TlBr revealed two traps with energies of 0.35 and 0.45 eV in PICTS spectra. The Pb-doped material revealed three levels with energies of 0.11, 0.45, and 0.75 eV. CL measurements in both materials correlate with optical transitions involving some of the identified levels. The ambipolar carrier lifetimes of Se-doped and Pb-doped TlBr were measured with microwave reflectivity transients and found to be significantly lower than the lifetime of undoped TlBr. [ABSTRACT FROM AUTHOR]