Background: This study aimed to identify the incidence and causes of a second rise in C-reactive protein (CRP) levels following spinal instrumentation surgery and to help determine how an abnormal CRP response should be interpreted and managed during postoperative care.Methods: The medical records of 948 patients who underwent instrumented spine fusion surgery and met the inclusion criteria were retrospectively reviewed to assess the frequency and causes of a second rise (SR) of CRP. A SR of CRP was defined when the CRP level after postoperative day 7 increased by more than 0.5 mg/dl from that at the previous time-point. The diagnostic cut-off value of CRP elevation for detection of surgical site infection (SSI) was determined. Cut-off values were analyzed using receiver operating characteristic (ROC) curves. Bayes' theorem was used to determine blood test posterior probabilities for SSI-positive cases using cutoff values of re-evaluated CRP levels.Results: SR of CRP occurred in 107 of the 948 patients. Of the patients with SR of CRP, 38 (35%) patients had developed SSI, 33 (31%) patients had causes other than SSI, and the remaining 36 patients had unidentified causes. Among the patients with SR, excluding those with causes other than SSI, the best diagnostic cut-off value of SR for detection of SSI was 3.04 mg/dl (area under the curve was 0.74). The posterior test probability was 84.4%.Conclusions: For patients with SR of CRP, who had no causes other than SSI, an SR value of 3.04 mg/dl correlated with a high probability of developing SSI. [ABSTRACT FROM AUTHOR]